Caution, Option controller connection, Thermostat (freeze protection) 26l1,2 – MITSUBISHI ELECTRIC PE-15MYC User Manual

Page 71

background image

- 70 -

FZ7

FZ4

FZ3

FZ2

FZ6

H

H

H

H

INDOOR UNIT

OUTDOOR UNIT

Thermostat (ambient temp.)

Auxiliary relay (fan O/D)

FZ2~7

Contactor (fan O/D)

52F2~7

26D5~8

Timer

2
CR1~3

Surge killer

Contactor (fan O/D)

X3~6

Auxiliary relay (defrost)

T1,2

Timer (defrost)

Note:1.The dotted lines show field wiring.

2.The figure in the parentheses show field supply parts.
3.Color of earth wire is yellow and green twisting.
4.Not specified color of wire is brown.
5.Specification subject to change without notice.

C1~8

Connector

Internal thermostat(compressor)

49C1,2

Compressor motor

Symbol

Terminal block

Over current relay(compressor)

Fan motor (outdoor)
Contactor (compressor)

Over current relay(fanI/D,O/D)

Contactor (fan I/D)

Crankcase heater

Transformer

Fuse (3.15A)

Fan motor (indoor)

TB1~6

MC1,2
MF1
MF2,3
52C1,2

51F1~5

CH1,2

Tr1~3

51C1,2

F1~3

Name

63H1,2

High-pressure switch

26D1~4

Thermostat (defrost)

52F1

FZ1,30FZ

Auxiliary relay (fan I/D)
Auxiliary relay
Auxiliary relay (heater)
Auxiliary relay (check)

Switch (operation mode)

X1,2

CZ1-1,2/2-1,2
HZ1,2
30CZ1,2

21S4-1,2


Switch (on)

<23WA>

Thermostat (room temp.)

4-Way valve

2.To protect the starting Compressor at the same time,Timer

<2> is installed. Therefore, do not change factory set value of this Timer.

OUTDOOR

Option controller connection.

Cooling or Heating
operation

FAN HI

4WV

COMP1

24VAC(L)

PAC-204RC (Option)
terminal no.

24VAC(N)

COMP2

2

3

Power (Neutral)

Fan operation

Cooling or Heating
operation

Reversing valve
for Heating operation

Power (Active)

Function

6

5

4

1

No.

TB3

Symbol

L3-1

L2-1

L1-1

L3-2

L2-2

L1-2

L3-2

L2-2

L1-2

L3-1

L2-1

L1-1

BLACK

WHITE

RED

52
F1

FZ1

C2

C1

51F1

63H2

51C2

F3

51

49C2

30

CZ2

CZ2-2

X2

X1

X5

X3

52
C2

S4-1

21

T1

C6

C4

C6

C4

CR3

2

2

F7

26D8

F7

F6

F6

F5

F5

52

52

52

52

52

52

6

6

5

7

6

5

FZ

FZ

FZ

FZ

FZ

FZ

F3

F3

F4

F4

F2

F2

52

52

52

52

52

52

4

3

3

2

2

3

FZ

FZ

FZ

FZ

FZ

FZ

26D7

26D6

FZ5

26D5

X1

26
D3

D1

26

X3

X3

X5

3

1

1

3

51C1

MC1

TB4

51C2

MC2

WHITE

BLACK

WHITE

BLACK

51F4

13

12

51F2

51F5

52F5

TB6

BLACK

WHITE

RED

3

2

1

BLACK

RED

MF3

WHITE

TB6

BLACK

WHITE

RED

52F7

52F6

Tr3

3

2

1

BLACK

RED

MF2

WHITE

RED

WHITE

BLACK

RED

WHITE

BLACK

TB5

TB5

52F2

52F4

51F3

52F3

Tr2

PUH-20MYC1-EU ··· 125A

CR2

CR1

1

GRAY

GRAY

GRAY

30
CZ1

30

CZ2-1

52
C1

CZ1

3

1

C5

C7

1

3

11

14

52F

HZ2

HZ1

1-2

CZ

1-1

CZ

TB3

13

12

11

13

12

11

14

TB3

2-2

CZ

HZ2

CZ
2-1

14

6

1-2

CZ

1-1

H

HZ1

4

C

CZ

3

TB3

2

5

SWITCH BOX (FIELD SUPPLY)

23

WA

H

C

SW1

HEAT

COOL

SW2

F2

(3.15A)

AC

24V

Tr1

AC

220~

240V

51F1

HZ2

2-2

CZ

CZ

2-1

C5

C7

X2

X4

X6

T2

X4

D4

26

26
D2

X4

T2

X6

21

S4-2

X2

T1

CH2

52

C2

52

C1

CH1

51

49C1

F2

63H1

51C1

30
FZ

FZ

30

FZ1

CZ2

30

F3 (3.15A)

BLACK

WHITE

RED

52C2

RED

BLACK

WHITE

RED

BLACK

WHITE

Caution,

1.To protect each Fan motor and Compressor from abnormal current,

Over current relays<51C1,2>,<51F1~5>are installed. Therefore,

do not change factory set value of Over current relays.

PE

PE

PEH-15,20MYA-EU ··· 30A

PUH-15MYC1-EU ··· 100A

F1

(3.15A)

52C1

CIRCUIT BREAKER
(FIELD SUPPLY)

BLUE

BLUE

BLACK

WHITE

RED

TB2

L1

L2

L3

N

CIRCUIT BREAKER
(FIELD SUPPLY)

MF1

52F1

RED

BLACK

WHITE

RED

RED

TB1

L1

L2

L3

N

Power supply,
3 Phase
380~415 Volt,
50Hertz

Power supply,
3 Phase
380~415 Volt,
50Hertz

HZ1

3

1

C3

C3

26L1

3

1

C8

C8

26L2

Thermostat (freeze protection)

26L1,2

PEH-15,20MYA-EU

(SPECIAL ORDER : LOW AMBIENT COOLING)