MITSUBISHI ELECTRIC PE-15MYC User Manual

Page 58

background image

- 57 -

PE-8,10MYC-EU

(SPECIAL ORDER : LOW AMBIENT COOLING)

Note:1.The dotted lines show field wiring.

2.The figure in the parentheses show field supply parts.
3.Color of earth wire is yellow and green twisting.

4.Not specified color of wire is brown.
5.Specification subject to change without notice.

Caution,
1.To protect each Fan motor and Compressor from abnormal

current, Over current relays <51C>, <51F1,2> are installed.

Therefore, do not change factory set value of Over current

relays.

H

OUTDOOR

1

1

3

2

C6

5

C4

C4

49F2

4

52F3

52F2

52F4

52
F3

52
F2

3

5

23C

BLACK

RED

MF2

WHITE

1

2

3

MF3

WHITE

BLACK

1

2

3

MC

RED

C4

C5

52F4

RED

WHITE

BLACK

52F2

52F3

CR1

CR2

GRAY

CH

N

F3(3.15A)

F1(3.15A)

(3.15A)

52C

CZ

30

49C

52C

N

15

TB5

BLUE

CZ2

14

63H

51F2

CZ2

CZ

30

51C

PE

PE

220
240V

24V

AC

AC

Tr

TB4

TB4

SWITCH BOX

(FIELD SUPPLY)

SW1

2

3

FZ

F2

CZ1

30FZ

52F1

14

RED

4

GRAY

15

FZ

15

GRAY

14

FZ

30

CZ2

BLUE

TB3

CZ1

PU-8,10MYC1-EU

C2

C1

3

2

1

1

BLUE

WHITE

RED

3

1

2

52C

BLACK

WHITE

RED

TB2

L1

L2
L3

CIRCUIT BREAKER
(FIELD SUPPLY)100A

PE-8,10MYC-EU CIRCUIT BREAKER

(FIELD SUPPLY)15A

51C

51F2

BLUE

RED

51F

MF1

WHITE

52F1

RED

WHITE

BLACK

BLACK

WHITE

BLACK

WHITE

RED

RED

RED

TB1

L1

L2

L3

Power Supply,

50Hertz

380 415Volt,

3Phase

Power Supply,

50Hertz

380 415Volt,

3Phase

52F1

23WA

Connector

(compressor)

(outdoor fan)

(indoor fan)

Internal thermostat

Internal thermostat

F1 3
Tr

49F2

Internal thermostat

49F1

52F1

23C

CZ1, 2

Surge killer

CR1, 2

C1~6

30CZ, FZ

Compressor motor

52F2 4

TB1 5

Over current relay

Fan motor (outdoor)
Contactor (compressor)

Over current relay(fanI/D,O/D)

Contactor (fan I/D)

Contactor (fan O/D)

Ambient temperature

Fuse (3.15A)

CH

Crankcase heater

Terminal block

Fan motor (indoor)

(compressor)

High-pressure switch

Auxiliary relay (fan)
Auxiliary relay (compressor)
Auxiliary relay (check)
Switch (on)
Thermostat (room temp.)

Transformer

Option controller connection.

24VAC(N)

FAN HI

COMP

24VAC(L)

PAC-204RC (Option)
terminal no.

2
3

Power (Neutral)

Fan operation

Cooling operation

Power (Active)

Function

4

1

No.

TB4

Symbol

5

4

C1

C1

51F1

49F1

3

1

C3

C3

26L

Thermostat (freeze protection)

26L

MF1

1

2

3

C1

1

2

3

C2

This circuit diagram shows connections.

(If the external static Pressure is less

than 30 Pa, change to connections.)

3

2

1

Attach the accessory

Remove