Internal thermostat, Option controller connection – MITSUBISHI ELECTRIC PE-15MYC User Manual

Page 54

background image

- 53 -

OUTDOOR

(3MIN)

TM

TM

CR1

CR2

GRAY

CH

F3(3.15A)

(3.15A)

F3(3.15A)

52C

CZ

30

49C

52C

15

TB5

BLUE

CZ2

14

63H

51F2

CZ2

CZ

30

51C

220
240V

24V

AC

AC

Tr

TB4

TB4

2

3

FZ

F2

CZ1

30FZ

52F

52F

14

RED

4

GRAY

15

FZ

15

GRAY

14

FZ

30

CZ2

BLUE

TB3

CZ1

C2

C1

3

2

1

1

BLUE

WHITE

RED

C5

C4

MC

3

1

2

1

2

3

BLACK

RED

MF3

WHITE

52C

BLACK

WHITE

RED

51C

3

2

1

51F2

WHITE

BLUE

RED

51F

MF1

WHITE

52F

MF2

RED

RED

WHITE

BLACK

BLACK

BLACK

WHITE

BLACK

WHITE

RED

RED

RED

PU-8, 10MYC1-EU

PE

3Phase

50Hertz

Power supply,
380 415Volt,

CIRCUIT BREAKER

(FIELD SUPPLY) 100A

TB1

L1

L2

L3

N

PE-8, 10MYC-EU

3Phase

50Hertz

Power supply,
380 415Volt,

CIRCUIT BREAKER

(FIELD SUPPLY) 15A

TB1

L1

L2

L3

N

PE

Note:1.The dotted lines show field wiring.

2.The figure in the parentheses show field supply parts.
3.Color of earth wire is yellow and green twisting.
4.Not specified color of wire is brown.

6.Specification subject to change without notice.

Caution,
1.To protect each Fan motor and Compressor from abnormal

current, Over current relays <51C>, <51F1,2> are installed.

Therefore, do not change factory set value of Over current

relays.

Connector

(indoor fan)
(compressor)

Internal thermostat

Internal thermostat

49F

CZ1, 2

Surge killer

CR1, 2

Timer (Anti short cycle)

TM

30CZ, FZ

Compressor motor

Terminal block

TB1 5

F1 3

Over current relay

Fan motor (outdoor)
Contactor (compressor)

Over current relay(fanI/D,O/D)

Contactor (fan I/D)

Crankcase heater

Transformer

Fuse (3.15A)

Fan motor (indoor)

(compressor)

High-pressure switch

Auxiliary relay (fan)

Auxiliary relay (compressor)

Auxiliary relay (check)
Switch (on)

Thermostat (room temp.)

C1~ 5

SWITCH BOX

(FIELD SUPPLY)

SW1

23WA

Option controller connection.

24VAC(N)

FAN HI

COMP

24VAC(L)

PAC-204RC (Option)
terminal no.

2
3

Power (Neutral)

Fan operation

Cooling operation

Power (Active)

Function

4

1

No.

TB4

Symbol

Thermostat (freeze protection)

26L

5.When PAC-204RC is used, Timer(TM)is unneccessary.

5

4

C1

C1

51F1

49F

3

1

C3

C3

26L

MF1

1

2

3

C1

1

2

3

C2

This circuit diagram shows connections.

(If the external static Pressure is less

than 30 Pa, change to connections.)

3

2

1

Attach the accessory

Remove

PE-8,10MYC-EU

(SPECIAL ORDER : ANTI SHORT CYCLE TIMER)