Connector surge killer run capacitor, Option controller connection – MITSUBISHI ELECTRIC PE-15MYC User Manual

Page 53

background image

- 52 -

OUTDOOR

TM
(3MIN)

TM

CR1

CR2

GRAY

CH

52F

FZ

FZ

30

52F

BLUE

30FZ

F3(3.15A)

51C

63H

51F2

CZ2

CZ

30

CZ

30

52C

CZ1

15

CZ2

14

49C

52C

GRAY

GRAY

BLUE

BROWN

RED

C1

C1

4

2

1

SW2(FIELD SUPPLY)

JUMPER

TB4

TB4

6

7

5

Low

Hi

C5

C4

15

15

6

5

RED

MC

3

2

1

C

BLACK

WHITE

MF3

CZ2

14

TB3

52C

14

BLUE

(3.15A)

RED

BLUE

RED

TB2
L

N

4

51C

3

2

1

51F2

CZ1

WHITE

51F1

MF1

52F

MF2

RED

RED

WHITE

BLACK

BLACK

BLACK

F2

WHITE

BLACK

WHITE

RED

RED

RED

TB1

L1

L2

L3

N

TB5

(3.15A)

F1

Tr

TB4

TB4

SWITCH BOX
(FIELD SUPPLY)

1

2

3

FZ

PU-7MYC

1

-EU

3Phase

50Hertz

Power supply,
380 415Volt,

CIRCUIT BREAKER

(FIELD SUPPLY) 100A

Single Phase

50Hertz

Power supply,
220 240Volt,

220
240V

24V

AC

AC

PE

PE

PE-7MYC-EU

CIRCUIT BREAKER

(FIELD SUPPLY) 15A

Connector
Surge killer

Run capacitor

(compressor)

Internal thermostat

CZ1, 2

C

Thermostat (freeze protection)

26L

CR1, 2

Timer (Anti short cycle)

TM

30CZ, FZ

Compressor motor

Terminal block

TB1 5

F1 3

Over current relay

Fan motor (outdoor)
Contactor (compressor)

Over current relay(fanI/D,O/D)

Contactor (fan I/D)

Crankcase heater

Transformer

Fuse (3.15A)

Fan motor (indoor)

(compressor)

High-pressure switch

Auxiliary relay (fan)
Auxiliary relay (compressor)
Auxiliary relay (check)
Switch (on)
Switch (Fan Hi-Low)
Thermostat (room temp.)

C1, 3~5

Note:1.The dotted lines show field wiring.

2.The figure in the parentheses show field supply parts.
3.Color of earth wire is yellow and green twisting.

4.Not specified color of wire is brown.

5.Please remove the jumper wire ( Mark) in the above

diagram if you use the Switch at local.

If the Switch is not used, the Fan motor

(indoor) drives at high speed.

7.Specification subject to change without notice.

6.When PAC-204RC is used, Timer(TM)is unneccessary.

Caution,
1.To protect each Fan motor and Compressor from abnormal

current, Over current relays <51C>, <51F1,2> are installed.

Therefore, do not change factory set value of Over current

relays.

SW1

23WA

Option controller connection.

24VAC(N)

FAN HI

COMP

24VAC(L)

PAC-204RC (Option)
terminal no.

2
3

Power (Neutral)

Fan operation

Cooling operation

Power (Active)

Function

4

1

No.

TB4

Symbol

3

1

C3

C3

51F1

26L

PE-7MYC-EU

(SPECIAL ORDER : ANTI SHORT CYCLE TIMER)

This manual is related to the following products: