Protect for cool air blow, Internal thermostat – MITSUBISHI ELECTRIC PE-15MYC User Manual

Page 67

background image

- 66 -

PEH-8,10MYA-EU

SPECIAL WIRING : ANTI SHORT CYCLE TIMER.,

(

PROTECT FOR COOL AIR BLOW.

)

OUT

DOOR

OUTDOOR

(3MIN)

TM

TM

17

16

X3

17

17

X3

16

16

CR1

CR2

GRAY

X1

X1

C6

3

C6

1

1

3

C7

5

4

C1

C1

49F

51F1

CH

BLUE

F3(3.15A)

(3.15A)

F3(3.15A)

X1

X2

52C

CZ

30

C7

26
D2

21

T1

S4

26
D1

X2

X3

X1

X2

X3

T1

49C

52C

13

15

HZ2

TB4 (In case of PUH-8,10MYE-EU)
TB5 (In case of PUH-8,10MYC1-EU)

BLUE

CZ2

14

63H

51F2

CZ2

CZ

30

51C

HZ2

220
240V

24V

AC

AC

Tr

HZ1

3

TB4

TB4

SWITCH BOX

(FIELD SUPPLY)

SW2

2

4

FZ

H

C

HZ1

F2

CZ1

30FZ

52F

52F

14

RED

5

13

GRAY

SW1

HEAT

COOL

15

FZ

15

GRAY

HZ2

14

FZ

30

CZ2

BLUE

23

WA

TB3

CZ1

13

C2

C1

3

2

1

1

BLUE

WHITE

RED

C5

C4

MC

3

1

2

1

2

3

BLACK

RED

MF3

WHITE

52C

BLACK

WHITE

RED

51C

3

2

1

51F2

WHITE

BLUE

RED

51F

MF1

WHITE

52F

MF2

RED

RED

WHITE

BLACK

BLACK

BLACK

WHITE

BLACK

WHITE

RED

RED

RED

PUH-8, 10MYE-EU
PUH-8, 10MYC1-EU

PE

3Phase

50Hertz

Power supply,
380 415Volt,

CIRCUIT BREAKER

(FIELD SUPPLY) 100A

TB1

L1

L2

L3

N

PEH-8, 10MYA-EU

3Phase

50Hertz

Power supply,
380 415Volt,

CIRCUIT BREAKER

(FIELD SUPPLY) 15A

TB2

L1

L2

L3

N

PE

Auxiliary relay (defrost)

Contactor (fan O/D)

Timer (Anti short cycle)

Timer (defrost)

Connector

(C5 is PUH-8,10MYC-EU only.)

(indoor fan)
(compressor)

Internal thermostat

Internal thermostat

49F

CZ1, 2
HZ1, 2

C1~7

Surge killer

CR1, 2

30CZ, FZ

Compressor motor

Terminal block

TB1 5

F1 3

Over current relay

Fan motor (outdoor)
Contactor (compressor)

Over current relay(fanI/D,O/D)

Contactor (fan I/D)

Crankcase heater

Transformer

Fuse (3.15A)

Fan motor (indoor)

(compressor)

High-pressure switch

Thermostat (defrost)

Auxiliary relay (fan)
Auxiliary relay (compressor)
Auxiliary relay (4-way valve)
Auxiliary relay (check)

Switch (operation mode)
Switch (on)
Thermostat (room temp.)

4-Way valve

Note:1.The dotted lines show field wiring.

2.The figure in the parentheses show field supply parts.
3.Color of earth wire is yellow and green twisting.
4.Not specified color of wire is brown.

6.Specification subject to change without notice.

Caution,
1.To protect each Fan motor and Compressor from abnormal

current, Over current relays <51C>, <51F1,2> are installed.

Therefore, do not change factory set value of Over current

relays.

Option controller connection.

FAN HI

4WV

COMP

24VAC(L)

PAC-204RC (Option)
terminal no.

24VAC(N)

2

3

Power (Neutral)

Fan operation

Cooling or Heating
operation
Reversing valve
for Heating operation

Power (Active)

Function

5

4

1

No.

TB4

Symbol

MF3 is only PUH-8,10MYC1-EU.

5.When PAC-204RC is used, Timer(TM)is unneccessary.

Thermostat (freeze protection)

26L

HZ1

3

1

C3

C3

26L

MF1

1

2

3

C1

1

2

3

C2

This circuit diagram shows connections.

(If the external static Pressure is less

than 30 Pa, change to connections.)

3

2

1

Attach the accessory

Remove

This manual is related to the following products: