beautypg.com

Ptz camera – Maxtor pmn User Manual

Page 10

background image

ETHERNET

RS-232C

AUDIO

FUNCTION

1 RS 485 D-
2 RS 485 D+
3 RELAY COM
4 RELAY NC
5 RELAY NO

6 ALARM GND
7 ALARM D4
8 ALARM D3
9 ALARM D2

10 ALARM D1

SPK MIC4 MIC3 MIC2 MIC1

1 2 3 4 5 6 7 8 9 10

4. Installation

7

5) Sensor Connection

Connect the Sensor to the SENSOR INPUT/OUTPUT on the Rear Panel of the system

6) Network Connection

RS-232C : Connect to PC to operate DVMR

NOTICE : Sensor input is RECOGNIZED as LOW when alarm signal is on a level with GND,

and it is recognized as HIGH when alarm signal is FLOATING or 5V. Following is internal circuit.

Internal Circuit

D1

5

V

Thus, there is a danger of damage, when the sensor input goes to a Negative level or
voltage higher than 5V.

7. TCP/IP SETUP

5. Operation

24

TCP/IP SETUP

IP ADDRESS
GATEWAY
SUBNET MASK
MAC ADDRESS
DHCP SETUP

SELECT , PRESS ENTER

1

2
3

4

4

3

MAC ADDRESS : It is unique ID number
provided by the manufacturer, and the user
should not change under any condition.

TCP/IP option of this DVMR system enables user to see live pictures and recorded pictures via internet
line, far apart from DVMR unit. To see live pictures or recorded pictures of DVMR, users must assign IP
address into DVMR together with Gateway and Subnet mask first, and then install Remote Viewer
Program included in the package on client PC.
For detail procedure for installing Remote Viewer Program and setting up, refer to manual for Remote
Viewer program included in the package.

SUBNET MASK : Enter numbers using
direction buttons and press [MENU] button.

SYSTEM SETUP

DISPLAY SETUP
CAMERA TITLE
TIME/DATE SETUP
ALARM/MOTION SETUP
RECORD SETUP
TCP/IP SETUP
MISCELLANEOUS
FACTORY DEFAULT

ALL ABOUT IMAGE RECOGNITION & PROCESSING

ALL ABOUT IMAGE RECOGNITION & PROCESSING

Terminal block

Pin 1

Alarm1

Pin 2

Alarm2

Pin 3

Alarm3

Pin 4

Alarm4

Pin 5

GND

Pin 6

NO( Normal Open )

Pin 7

NC( Normal Close)

Pin 8

COM

Relay output : COM+NC, COM+NO OR COM+NC+NO

Alarm input : Short-circuit between Alarm1, Alarm2, Alarm3 or Alarm4 and GND is recognized as alarm.

For more details, refer to arrangements RS-232c pins in page 32.

RS 485 : Connect to PTZ camera

RJ-45 (ETHERNET) : Connect to LAN, WAN or Internet

5

DHCP SETUP : In case you connect DVMR
unit to LAN network under router/Gateway/IP
sharer which has DHCP server function, set
DHCP SETUP at DHCP, and DVMR unit automatically gets
IP data automatically during the process of booting.
In case you connect DVMR unit to leased line with static IP, Router/Gateway connected ADSL(with
static IP or dynamic IP), you are requested to set DHCP at MANUAL and input IP data manually. For
details, refer to Remote Viewer manual.

5

TCP/IP SETUP

PTZ

CAMERA

G
N
D

D
4

D
3

D
2

C
O
M

N
C

N
O

D
1

ALARM

RELAY

D
--

D
+

IP ADDRESS : Enter numbers using direction buttons and
press [MENU] button.

GATEWAY : Enter numbers using direction
buttons and press [MENU] button.

1

2

1) Concept of accessing to DVMR unit via IP network

PC

DVMR unit

PTZ

Camera

LAN, WAN, or Internet

Client program
(remote viewer)

TCP/IP setup

2) Conditions of IP network

a) Accessing to DVMR unit in the same Intranet(LAN)

DHCP server

Router/Gateway
IP Sharer

DVMR unit

PC

LAN

b) Accessing to DVMR unit via Internet line

Internet

PC

Leased line : Manual
Cable modem : Automatic

Leased line w/ static IP

Cable modem w/ dynamic IP

DVMR unit

Client program
(remote viewer)

Internet

PC

ADSL

modem

w/

dynamic IP

or

static IP

DVMR unit

Client program

(remote viewer)

Router

or

Gateway

PPPoE

protocol

Port Forwarding

(IP Forwarding)

Manual

For details of TCP/IP setting in DVMR unit and PC, refer to “Remote Viewer manual” included in the package.

DHCP SETUP

DHCP SETUP

DHCP SETUP

Automatic

Other devices

24

AUDIO : 1 audio input/channel, 1 audio output from selected channel.

COM NC NO GND D4 D3 D2 D1