beautypg.com

Preparation for long-term storage – Multiquip High Pressure Centrifugal Pump (Honda GX340K1PKT2/GX340U1PKT2 Gasoline Engine) QPT305SLT User Manual

Page 23

background image

Qp305SLT/QpT305SLT CeNTRIFUgaL pUMp • opeRaTIoN aNd paRTS MaNUaL

— Rev. #1 (10/11/10) — page 23

preparatiOn FOr lOnG-terM stOraGe

pUMp SToRage

For storage of the pump for over 30 days, the following is

required:

„

Drain the fuel tank completely.

„

Run the engine until the fuel in the injection system is

completely consumed.

„

Completely drain used oil from the engine crankcase

and fill with fresh clean oil, then follow the procedures

described in the engine manual for engine storage.

„

Remove the drain plug from the pump and drain out any

water left in the housing.

„

Cover suction and discharge ports with duct tape to

prevent any foreign matter from falling into pump.

„

Cover pump and engine with plastic covering or

equivalent and store in a clean, dry place.

„

To protect the water-cooled seals, place one-half pint

of lubricating oil (new or used) through the discharge

opening on the pump and crank the engine several times.

This will prevent excessive corrosion and also keep the

mechanical seal lubricated.