beautypg.com

Operation – Multiquip High Pressure Centrifugal Pump (Honda GX340K1PKT2/GX340U1PKT2 Gasoline Engine) QPT305SLT User Manual

Page 18

background image

page 18 —Qp305SLT/QpT305SLT CeNTRIFUgaL pUMp • opeRaTIoN aNd paRTS MaNUaL — Rev. #1 (10/11/10)

6. Grasp the starter grip (See Figure 11) and slowly pull

it out. The resistance becomes the hardest at a certain

position, corresponding to the compression point. Pull

the starter grip briskly and smoothly for starting.

Figure 11. Starter Grip

7. If the engine has started, and the choke lever was

moved to the CLOSED position to start the engine,

gradually move the choke lever lever to the OPEN

position as the engine warms up.If the engine has not

started repeat steps 1 through 6.

Figure 12. Choke Lever (Open)

8. Before the pump is placed in to operation, run the

engine for several minutes. Check for fuel leaks,

and noises that would be associated with a loose

component.

9. To begin pumping, place the throttle lever (See Figure

13) in the “

RUN

position.

Figure 13. Throttle Lever (Run)

SToppINg THe eNgINe

Normal Shutdown

1. Move the throttle lever to the IDLE position (See Figure

14) and run the engine for three minutes at low speed.

Figure 14. Throttle Lever (Idle)

2. After the engine cools, turn the engine ON/OFF switch

to the “OFF” position (See Figure 15).

Figure 15. Engine O/OFF Switch (OFF)

3. Place the fuel shut-off lever (SeeFigure 16) in the OFF

position.

Figure 16. Fuel Valve Lever (OFF)

Emergency Shutdown

1. Move the throttle lever quickly to the IDLE position, and

place the engine ON/OFF switch in the OFF position.

CaUTIoN

ALWAYS run engine at full speed while pumping.

OperatiOn