beautypg.com

Pre-installation information – Monessen Hearth Direct Vent Gas Insert IDV490NVC User Manual

Page 6

background image

6

57D0016

PRE-INSTALLATION INFORMATION

INSTALLING ABOVE 2000 FEET

• In the USA, the appliance must be derated 4% for every 1,000 ft above 2,000 ft elevations.
• In Canada, these appliances are certified for altitudes of 0 – 2000 ft, and must be de-rated by 10 percent for installations

between 2000 and 4,500 ft. (derate an additional 4% for every 1,000 ft. above 4,500 ft. elevations).

The IDV490NVC, IDV490PVC, IDV380NVC, and 380IDVPVC are equipped with a variable output gas control.

ORIFICE SIZES, PRESSURES AND BTUs

NATURAL GAS

PROPANE GAS

Manifold Press: (W.C.)

3.5"

Manifold Press: (W.C.)

10"

Maximum Supply Pressure 10.5"

Maximum Supply Pressure

13"

Minimum Supply Pressure

4.5"

Minimum Supply Pressure

11"

NOTE: IDV490NVC, IDV490PVC, IDV380NVC, and IDV380PVCinserts work without any electrical supply.

Blower must be attached to 110/120 VAC.

INSTALLATION PLANNING

Plan for the installation of your insert. This includes determining the size of fireplace in which unit is to be installed, length of

venting to be used, and finishing details, and whether any optional accessories (i.e. wall switch, or remote control) are desired.

Consult your local building code agency to ensure compliance with local codes, including permits and inspections.

Model Number

IDV490NVC

IDV490PVC

IDV380NVC

IDV380PVC

NATURAL

PROPANE

NATURAL

PROPANE

Max. Btu/hr Input

40,000

37,500

30,500

28,000

Min. Btu/hr Input

26,500

29,000

20,500

22,000

Orifice sizes (as shipped)

#30

#50

#35

#53