VENT INSTALLATION

MANIFOLD REMOVAL AND INSTALLATION

The manifold is shipped attached to insert. It may be removed to allow tight installation. Mani-

fold may be loosened and rotated for desired pipe location.

1. Remove brick liner and baffle.
2. Remove manifold. Place manifold

in fireplace.

3. Route flex vent through chimney

from above. See Figure 10. Leave

an extra 3" (914mm) at the top.

4. Attach flex vent to manifold. See

Figure 11. Seal with silicone and

attach with screws.

5. Place manifold in an upright

position. Have someone pull

on the excess flex vent. Figure

12. Temporarily attach flex vent

to top of chimney. Leave some

extra slack in flex vent.

6. Slide insert into place. Guide

the manifold over the insert

until it is fully in place.

Figure 13.

7. Remove any slack from flex

vent. Attach manifold to insert.

Figure 13.

8. Remove any excess slack in

flex line. Attach vent termina-

tion. Figure 13.

Figure 12 - Pulling On

Excess Flex Vent

Figure 13 - Sliding Insert

Into Place

Manifold

Chimney

Figure 10 - Placing

Manifold Into Fireplace

Figure 11 - Attaching

Flex Vent to Manifold

Flex Vent

Extra 3"

(914mm)

Manifold

Flex Vent

Chimney

Manifold

Chimney

Excess

Flex Vent

Slack in

Flex Vent

Manifold

Bracket

Nut

Insert

Excess Slack Taken

Out of Flex Vent

Vent

Termination

Chimney

9. Replace

baffle and

brick liner.