MAINTENANCE

YEARLY SERVICE PROCEDURE

Failure to inspect and maintain heater may lead to improper combustion and a potentially dangerous situation. A qualified

technician should do the following once a year.
1. Check pilot flame. Flame should touch approximately

3

/

8

" of the top of thermopile and touch top of thermocouple. See

Figure 43. If not, contact dealer for service.

2. Turn gas control knob to “OFF” position to shut off gas to heater. See step “To Turn Off Gas”, page 29. Let heater cool

for 15 minutes. Remove faceplate (see instructions included with face plate) and glass. See Page 31.

3. Carefully remove log set. If logs are severely deteriorated, replace logs. Check logs for sooting. A small amount of soot

along bottom of logs is normal. If excessive sooting is found, heater must be adjusted. Contact dealer where you bought

heater.

4. Clean burner and burner ports. See Figure 44.
5. Replace log set and rock wool per instructions on pages 21-23. Replace glass. Make sure gasket along perimeter of glass

contacts face of firebox and forms an airtight seal. Realign if airtight seal is not formed. Replace glass and glass frame

if damaged.

6. Inspect area behind face plate. Clean if necessary. Check gas control valve and all gas lines. If damaged, do not use

heater. Contact your dealer.

7. Start pilot and turn on main burner. Flames should be orange/yellow and not touch top of firebox. If pilot or main burners

do not burn correctly, contact your dealer for service. Monitor blower operation.

Figure 43 - Before taking unit

apart, check pilot flame. Flame

should touch thermocouple

and thermopile

Thermopile

Thermocouple

Check Burner Ports

Figure 44 - Checking Burner Ports and Burners