beautypg.com

Caution insert installation, Caution, Warning – Monessen Hearth Direct Vent Gas Insert IDV490NVC User Manual

Page 17

background image

57D0016

17

Figure 14 - External Regulator with Vent Pointing

Down (Propane/LP Only)

Use only new black iron or steel pipe.
Internally tinned copper or copper
tubing can be used per National
Fuel Code, section 2.6.3, providing
gas meets hydrogen sulfide limits,
and where permitted by local codes.
Gas piping system must be sized to
provide minimum inlet pressure (listed
on data plate) at the maximum flow rate
(BTU/hr). Undue pressure loss will
occur if the pipe is too small.

CAUTION

INSERT INSTALLATION

CHECK GAS TYPE

Use proper gas type for the insert you are installing. If you have conflicting gas type, do not install insert. See dealer where

you purchased the insert for proper insert according to your gas type.

INSTALLING GAS PIPING TO INSERT LOCATION

For propane/LP units, never connect insert directly to the propane/LP supply. This
burner system requires an external regulator (not supplied). Install the external regulator
between the burner system and propane/LP supply.

CAUTION

A qualified installer or service person
must connect appliance to gas supply.
Follow all local codes.

W

ARNING

INSTALLATION ITEMS NEEDED
Make sure you have the items listed below before installing appliance.
• External regulator (supplied by installer) • Piping (check local codes)

• Sealant (resistant to propane/LP gas)

• Test gauge connection*

• Sediment trap (optional but recomended)

• Tee joint

• Pipe wrench

• approved flexible gas line with gas connector (if allowed by local codes — not provided)
* A CSA design-certified equipment shutoff valve with

1

/

8

" NPT tap is an acceptable alternative to test gauge connection.

Purchase the CSA design-certified equipment shutoff valve from your dealer.
For propane/LP connections only, the installer must supply an external regulator. The external regulator will reduce incoming

gas pressure. You must reduce incoming gas pressure to between 11 and 13 inches of water. If you do not reduce incoming

gas pressure, burner system regulator damage could occur. Install external regulator with the vent pointing down as shown

in Figure 27. Pointing the vent down protects it from freezing rain or sleet.

External

Regulator

100 gal. (min)

Propane/LP

Supply Tank

Vent

Pointing

Down

When using copper or flex connectors use only fittings

approved for gas connections. The gas control inlet is

3

/

8

" NPT.