ZERO-CLEARANCE (METAL) FIREPLACE REQUIREMENTS

• The damper and grate must be removed.
• The smoke shelf, internal baffles, screen, refractory, and metal or glass doors may be removed (if applicable).

• Installer must attach red warning plate to the inside of the firebox of fireplace with

screws supplied.

• Do not cut any sheet metal parts of the fireplace in which this gas fireplace insert is

installed. THIS IS STRICTLY PROHIBITED!

• If factory-built fireplace has no gas access hole(s) provided, drill a 1.5" (37.5mm) or

less through lower sides or bottom of firebox. You must plug the access hole with
noncombustible insulation after gas supply line has been installed.

• If your factory-built fireplace has air passages on the face for zero capabilities, DO

NOT BLOCK THESE PASSAGES!

W

ARNING

• Do not remove or alter the insulation or any structured rigid frame members (metal sides, floor, door frame, face of the

fireplace, etc.).

INSTALLATION

Figure 5 - Metal Fireplace Zero-Clearance Requirements

IMPORTANT:Please review the following carefully.
It is normal for inserts fabricated of steel to give off some expansion and/or contraction noises during the start up or cool

down cycle. Similar noises are found with your furnace heat exchanger or car engine.
It is not unusual for your insert to give off some odor the first time it is burned. This is due to the curing of the paint and any

undetected oil from the manufacturing process.
Please ensure that your room is well-ventilated. OPEN ALL WINDOWS DURING INITIAL BURN OFF/
CURING PHASE.

Burn your insert for a least six (6) hours on “HIGH” the first time you use it. Place fan in the “OFF” position during

this time.