VENT INSTALLATION

VENT REQUIREMENTS

• Make sure the exhaust pipe on heater connects

to exhaust portion of cap. Attach flex liners. See
Figure 6.

• Do not crimp or rupture liner when bending it into

chimney offsets.

W

ARNING

Figure 6 - Venting Unit

Exhaust

Inlet

Maximum Height

40' (12.9 M)

Minimum Height

10' (3 M)

Maximum

1' (305mm)

Offset at

Base of

Insert

• Make sure you have the following before installing

490 unit:

• 4" and 3" UL 1777 Listed gas liner for air

inlet and exhaust

• Vertical termination kit (AI42TK43A)

• Make sure you have the following before installing

380 unit:

• 3" and 3" UL 1777 Listed gas liner for air inlet and

exhaust

• Vertical termination kit (AI31TK33A)

• The exhaust vent must reline the entire length of chimney and terminate above chimney top.
• Vent must meet all vent manufacturerʼs requirements when installed.