VENT INSTALLATION

ALTITUDE CONSIDERATIONS

This heater has been tested at altitudes ranging from sea level to 4,500 feet (USA), 0-2000 feet (Canada). In this testing,

heater with standard orifice burns correctly with just an air shutter adjustment. If you need to resize orifice for use at high

altitude, contact your dealer.

Failure to adjust air shutter properly may lead to
improper combustion which can create a safety
hazard. Consult your dealer or installer if you
suspect an improperly adjusted air shutter

W

ARNING

Figure 7 - Connecting Exhaust Pipe to Heater

Exhaust

(centered on unit)

Inlet

490 Unit - 4" and 3" UL

1777 Gas Liner

380 Unit - 3" and 3" UL

1777 Gas Liner

Termination Kit

490 Unit - AI42TK43A
380 Unit - AI31TK33A

Apply high-temperature silicone

to lines on both ends and

secure with two (2) screws.