AIR SHUTTER ADJUSTMENT (NATURAL GAS ONLY)

ADJUSTING THE AIR SHUTTER

The venturi of the burner is equipped with an air shutter. The opening of the venturi has been set at

1

/

4

" for Natural Gas and

fully open for Propane installation at sea level. The burner on Natural Gas Models may be adjusted for high altitude as fol-

lows:

• To increase air mixture, open the shutter more. This will reduce soot formation. See Figure 38.

• To decrease air mixture, close the shutter. Flames will be more yellow. See Figure 39.

Figure 39 - Pull Adjustment Lip Down to Close Air Shutter

Figure 38 - Push Adjustment Lip Up to Open Air Shutter

Air Shutter

Air Shutter