Ac current, Ra-kit/h return amplifier, Adu/qadu automatic drive unit – Motorola BT100 User Manual
Page 49
A-2
Specifications
BT100 Installation and Operation Manual
AC Current
AC Voltage
One-way
With RA-Kit
90 VAC
0.75 A
0.80 A
75 VAC
0.91 A
0.96 A
60 VAC
1.15 A
1.22 A
53 VAC
1.31 A
1.39 A
45 VAC
1.57 A
1.66 A
38 VAC
1.90 A
2.00 A
RA-Kit/H Return Amplifier
Parameter Specification
Passband (S–split)
5 through 40 MHz
Gain, station (minimum)
17.5 dB
Flatness
±0.75 dB
Level control
Fixed pads, JXP-
∗B, input and output
Performance – reference frequency (MHz)
40
At typical output
35 dBmV, flat
Channels
6 NTSC
Crossmod (worst case)
–74 dB
CTB (worst case)
–86 dB
CSO (worst case)
–82 dB
Noise figure
12.5 dB
Power requirements
24 VDC, 125 mA
ADU/QADU Automatic Drive Unit
Parameter Specification
Pilot channel
See current catalog
Adjacent channel frequency
±6 MHz
Minimum BT100 output at pilot frequency
+36 dBmV
ALC stiffness
±0.3 output change for ±3.0 dB input change
Power requirement
24 VDC, 75 mA