2-12

Overview

BT100 Installation and Operation Manual

Ingress Control Switch

The ingress control switches (ICS) provide return-path signal attenuation or cutoff in the

BT100. An ICS is required for each output port. Therefore the standard four output BT100

requires four ICS’s. Switching is accomplished through the frequency agile LIFELINE

status-monitoring transponder, which you can purchase directly from AM Networks.
Figure 2-12 illustrates the LL-BTA-HMS and the required cable connections to the electronics

chassis.

Figure 2-12
LL-BTA-HMS status monitor

The ICS provides a means of isolating sources of ingress from a centralized location. Using a

downstream command through the LIFELINE status-monitoring system, you can attenuate the

return path through the amplifier by 6 dB or by 38 dB. By reducing the ingress level at the

headend or monitoring point, you can further isolate the ingress source. After you isolate an

ingress source to the last possible amplifier, node, or line extender, you can shut the return path

off at that location. This limits the impact of the ingress on the remainder of the network while

eliminating the source of ingress.