beautypg.com

Appendix a specifications, Model bt100, Specifications – Motorola BT100 User Manual

Page 48

background image

BT100 Installation and Operation Manual

Appendix A

Specifications

Specifications are valid over the given bandpass and operating temperature range of

−40°F to

+140

°F (−40°C to +60°C). Specifications are stated typical unless otherwise noted, and are

subject to change. Refer to the Motorola CHS web site or contact your account representative for

the latest specifications.

Model BT100

Specification Forward

Amplifier

Passband

52 through 1003 MHz

Gain

Full

46 dB (with SFE-*-*)

Operational

42 dB (with SFE-*-* and slope reserves)

Flatness

52 through 1003 MHz

±0.70 dB maximum

Level control, automatic

Bode board using ADU/QADU/TDU

Gain control

Fixed pads, JXP-

∗B

Performance - reference frequency
(MHz)


1003/550/52

At typical output (dBmV)

45/44/37

Channels

79 analog/320 MHz
digital (suppressed by
6 dB)

Crossmod (worst case)

–66 dB

CTB (worst case)

–75 dB

CSO (worst case)

–71 dB

Noise figure

At 52 MHz

10 dB (with SFE-1)

At 1003 MHz

10 dB (with SFE-1)

Interstage equalizer, BDR-1G

14

±1 dB

Hum modulation

–70 dB

Return loss, input/output

16 dB at operational level

Test points, input/output

20

±1.0 dB

Housing dimensions

21.6 L

× 10.6 W× 7.7 D inches (54.9 Ч 26.9 Ч 19.6 cm)

Weight

27 pounds (12.25 kg)