External remote terminal 2, Printing (special) – MITSUBISHI ELECTRIC CP900E User Manual
Page 32

32
5
2
1
4
3
6 7 8
Pin No.
22k
Ω
22k
Ω
10k
Ω
100
Ω
DTC124EK
DC5V
1k
Ω
74LVC125
10k
Ω
100
Ω
DC5V
To VCP
To VCP
From VCP
To VCP
2
6
3
Circuit inside the VCP
5
MEMORY
BUSY2
REMOTE
4
BUSY1
74LVC125
10k
Ω
100
Ω
DC5V
TTL level
TTL level
56k
Ω
EXTERNAL REMOTE TERMINAL 2
The image can be stored in memory and printed by sending the remote signal through
the external remote terminal on the rear panel.
•
Make out the necessary circuit to use this function by referring to the following.
2
2
2
2
2
EXTERNAL REMOTE TERMINAL SIGNAL ALLOCATION (MINI
DIN8PIN)
Pin No.
Function
Description
1
Ground
Earth
2
MEMORY
Memory : When the signal becomes “LOW” from “HIGH”, the
image is stored in memory. (When the signal has
been “LOW” for 15ms or more, the image is stored
in memory. See page 51, 52.)
3
BUSY2
Refer to the BUSY LEVEL setting of REMOTE SET in
SERVICE MENU. See page 52.
4
BUSY1
Refer to the BUSY LEVEL setting of REMOTE SET in
SERVICE MENU. See page 52.
5
When the signal becomes “LOW” from “HIGH”, the image is
stored in memory. (When the signal has been “LOW” for 15ms
or more, the image is stored in memory.)
6
REMOTE
The same functions as the supplied remote control can be
controlled.
7
Unused
8
DC3V
Power supply for the remote control DC 1mA Max.
•
When the signal from BUSY terminal is received with TTL level, keep the following.
| I
OL
| = 2mA or less, | I
OH
| = 1mA or less
| I
OL
| means the current flowing into the unit at Low output, | I
OH
| means the
current flowing out of the unit at High output.
•
Just after completing printing, there is a period that memory signal is not accepted.