beautypg.com

Sprayer will not run – Graco Inc. 1095 HI User Manual

Page 19

background image

Troubleshooting

311365G

19

Sprayer Will Not Run

(See following page for steps)

Remove control box cover. Turn
sprayer ON. Observe control
board status light on control
board (see page 13).

No light

Once

Normal operation

Light on
Continuously

Control board
commanding
motor to run

Flashing

See Error Code
section for further
troubleshooting

Connect a test

transducer to the

board. Does the

motor run?

Replace

potentiometer.

Pressure switch.

See Step 3. Is the

proper reading

present through the

thermal switch

wires?.

Replace the

ON/OFF switch.

See step 4. Does

the motor run?

See Step 1. Do

you have over
100 AC volts?

See Step 2. Do

you have over

100 AC volts?

Repair or

replace

power cord.

If motor is hot, let cool and

retest. If Step 4 still shows

incorrect resistance, replace

motor. The motor has

a defective thermal device.

Replace the

transducer

Replace the

control board.

YES

YES

YES

NO

NO

NO

NO

YES

YES

NO