Environmental specifications – Gateway ALR 9200 User Manual
Page 189
Specifications 177
Environmental Specifications
The following specifications identify maximum environmental
characteristics. At no time should the server run under conditions which
violate these specifications.
Table 36: Environmental Specifications
Variable
Requirements
Temperature
Maximum rate of change = 10°C per hour
Nonoperating
–40° to 70 °C (–55° to 150 °F)
Operating
10° to 35 °C (41° to 95 °F); derated 0.5 °C for every
1000 ft (305 m)
Altitude
10,000 ft max
Humidity
Nonoperating
95% relative (noncondensing) @ 30°C (86°F)
Operating wet bulb Not to exceed 33 °C (91.4 °F) (with diskette drive or
hard disk drive)
Shock
Operating
2.0 g, 11 msec, 1/2 sine
Packaged
Operational after 30-inch free fall (cosmetic damage
might occur)
Acoustic noise
< 50 dBA w/ two power supplies at 28 °C +/- 2 °C
< 55 dBA w/ three power supplies at 28 °C +/- 2 °C
Electrostatic
discharge (ESD)
Tested to 20 kilovolts (kV) per Intel environmental test
specifications; no component damage
AC Input Power
100-120 V
∼
100-120 V
∼
, 7.6 A, 50/60 Hz
200-240 V
∼
200-240 V
∼
, 3.8 A, 50/60 Hz
3424.boo Page 177 Wednesday, September 2, 1998 9:23 AM