0) troubleshooting guide – Gas-Fired Products PTS Series 100 User Manual
Page 44

Form #43343530
July 08
–43–
22.0) TROUBLESHOOTING
GUIDE
Turn on the gas valve?
No
Ye
s
Is
the
knob
on
the
gas
valve turned to the ON position?
No
Ye
s
Are the blue wires secure in the terminals and firmly on the ignition module terminals?
Move orange wire to NO terminal. Rest
art
troubleshooting.
Replace motor
.
Remove any obstructions. Repeat st
art up. If motor will
not run. replace motor
.
No
Ye
s
Disconnect
the
power
and
check
the
blower
wheel. Does it turn freely?
No
Ye
s
During st
art up, is
there 120V between ground and the IND terminal on the module?
Clean out hoses and probes.
Switch hoses on the pressure t
ap
s.
Check
NO
terminal
of
the air switch connection. Replace red light.
No
Ye
s
Turn on line volt
age
and
adjust
thermost
at
to
the
highest
setting.
Does the red monitoring
light
come
on?
No
Ye
s
Does the blower come on?
No
Ye
s
Does the LED on the ignition module flash once?
No
Ye
s
Is
the
black
tap
on
the
air switch connected to the upper probe?
Check
the
probes
and
hoses
to
the
air
switch
are they clear and unobstructed?
Replace air switch.
No
Ye
s
Is
120V
at
the
terminal
block in the blower?
Check line volt
age
circuit. Rep
air fault.
No
Ye
s
Is there 120V between ground and the
L1
terminal
on
the
module?
No
Ye
s
Check terminals for continuity and rep
air
.
No
Ye
s
Is the LED on the ignition module steady ON?
No
Ye
s
Is
there
24V
between
the inlet to the fuse carrier and the ground?
No
Ye
s
Is there 24V on the other side of the fuse carrier?
No
Ye
s
Is
there
24V
between
both terminals of the TISS and ground?
No
Ye
s
The
TISS
has
broken
continuity
. Check the
first
tube
and
reflector
is there a hole?
Check
TISS wire for
a
break
if
it
is
close
to
the terminal rep
air
.
Otherwise replace TISS wire.
Replace heat exchanger tube, reflector and
TISS.
No
Ye
s
Is
there
24V
between
both terminals of the thermost
at
connection
and ground?
No
Ye
s
Does
the
system
have
a 24V individual thermost
at?
No
Ye
s
Is
120V
at
the
terminal
block in the blower?
Check
that
red
wire
is
connected
to
TH
from
air switch terminal C. Rep
air connection.
Replace ignition modules.
Rep
air or replace
jumper check all wire terminals.
Rep
air or replace
thermost
at. Check
external wiring.
Replace ignition module.
Check terminals for continuity at transformer
. If they
are good, replace transformer
.
if fuse carrier is tight and the fuse has no continuity
, replace
the
fuse.
No
Ye
s
Does the blower st
ay
on?
No
Ye
s
Does the LED on the ignition module flash once?
No
Ye
s
Is the orange wire from
PSW
connected
to
the
NO
terminal
of
the air switch?
No
Ye
s
Are air switch terminals jumpered?
Remove jumper
, air
switch must be open circuit first for blower to operate.
Air switch is stuck in the closed position. Replace air switch.
Move black light wire to NO terminal of the air
switch.
Rest
art
the
troubleshooting.
No
Ye
s
Does the low fire amber
light
come
on?
No
Ye
s
Is the LED on the ignition module steady ON?
No
Ye
s
Af
ter 15 seconds
post purge is there 24V
between
V1
and
V2 ignition module terminals?
Replace ignition module.
Replace ignition module.
Rep
air connection.
Rest
art
troubleshooting.
No
Ye
s
Are the black wires to the amber light securely on the gas valve terminals?
Rep
air connection.
Rest
art
troubleshooting.
Replace amber light. Rest
art
troubleshooting.
Troubleshooting continued
on
the
next
page.