8.2)
HEATER ASSEMBLY / JOINING OF TUBE SECTIONS
Typical
Assembly Overview
(PTS 40FT
Shown)
4"OD x 10Ft.
T
ube
See section
7
for required tubes.
Tube
Support
Bracket
U-Bolt Clamp & 5/16" Hex Nut
s
Mounting
Flange
24 Hole for
Aluminized S
teel
Tubes
6 Hole for
Alumi-Therm S
teel
Tubes
Wire Hanger
Gasket
Burner Box
Flue Termin
a
5 hanging point
s to be used for suspension for a typical 40f
t
long system.
There must be two hanging point
s on the first
tube and one on each of the other tubes
Maximum 6 dist
ance
from burner box to the tube support/hanger bracket.
8
- 9
¼
8
- 10
8
- 10
Not Less Than 10
#10 Self-Drill Screws (T
ypical all tube support
s,
tube couplings and flue terminal.)
Typical Overlap
Turbulator (See specifications section 5 for required quantities.)
Tube Coupling (T
ypical each tube joint
.)
Burner Box Suspension Chain