Product specs — 10 tons, 10 t, Roduct – Goodman Mfg CPC CONVERCIAL SS-CPC90-150 User Manual

Page 5: Pecifications

background image

4

www.goodmanmfg.com

SS-CPC90-150

SS-CPC90-150

www.goodmanmfg.com

5

P

roduct

S

PecificationS

P

roduct

S

PecificationS

P

roduct

S

PecificationS

— 10 t

onS

CPC120

***3B***A*

CPC120

***3B***B*

CPC120

***3V***A*

CPC120

***4B***A*

CPC120

***4B***B*

Cooling Capacity
Total BTU/h

118,000

116,000

116,000

118,000

116,000

Sensible BTU/h

87,300

84,700

84,700

87,300

84,700

EER / IEER

11.5 / 11.5

11.3 / 11.5

11.3 / 13.0

11.5 / 11.5

11.3 / 11.5

Decibels

83

83

83

83

83

ARI Reference #s

5728006

5728007

5696558

5728006

5728007

Evaporator Motor / Coil
Motor Type

Belt Drive

Belt Drive

2-Speed Belt

Belt Drive

Belt Drive

Indoor Nominal CFM

3,500

3,500

3,500

3,500

3,500

Indoor motor FLA (Cooling)

7.8

7.8

6.4

3.9

3.9

Horsepower - RPM

2.0/1725

2.0/1725

2.0/1725

2.0/1725

2.0/1725

Piston Size (Cooling)

0.086

0.086

0.086

0.086

0.086

Filter Size (Qty)

(4) 16 x 24 x 2

(4) 16 x 24 x 2

(4) 16 x 24 x 2

(4) 16 x 24 x 2

(4) 16 x 24 x 2

Drain Size (NPT)

¾"

¾"

¾"

¾"

¾"

R-410A Refrigerant Charge Cir #1 & #2

220 oz.

125 oz.

125 oz.

220 oz.

125 oz.

Evaporator Coil Face Area (ft²)

10.2

10.2

10.2

10.2

10.2

Rows Deep / Fins per Inch

4 / 14

4 / 14

4 / 14

4 / 14

4 / 14

Belt Drive Evap Fan Data
# of Wheels (D x W)

(1) 15" x 15"

(1) 15" x 15"

(1) 15" x 15"

(1) 15" x 15"

(1) 15" x 15"

Motor Sheave / Blower Sheave

VL40 / AK74

VL40 / AK74

VL40 / AK74

VL40 / AK74

VL40 / AK74

Belt

AX51

AX51

AX50

AX51

AX51

Condenser Fan / Coil
Quantity of Condenser Fan Motors

2

2

2

2

2

Horsepower - RPM

⅓ - 1,075

⅓ - 1,075

⅓ - 1,075

⅓ - 1,075

⅓ - 1,075

Fan Diameter / # Fan Blades

22 / 3

22 / 3

22 / 3

22 / 3

22 / 3

Outdoor Nominal CFM

8,200

8,200

8,200

8,200

8,200

Face Area (ft²)

32.4

35.2

35.2

32.4

35.2

Rows Deep - Fins per Inch

2 / 2 - 22

2 X2 / 27±1

2 X2 / 27±1

2 / 2 - 22

'2 X2 / 27±1

Compressor
Quantity / Type / Stage

2 / Scroll / 1

2 / Scroll / 1

2 / Scroll / 1

2 / Scroll / 1

2 / Scroll / 1

Compressor RLA / LRA ea.

16/110.0

16/110.0

16/110.0

7.8/52.0

7.8/52.0

Electrical Data
Voltage/Phase/ Frequency

208/230-3-60

208/230-3-60

208/230-3-60

460-3-60

460-3-60

Standard Max Static

1.4"

1.4"

1.4"

1.4"

1.4"

Outdoor Fan RLA ea.

2.40

2.40

2.40

1.20

1.20

Total Unit Amps

45

45

43

22

22

Min. Circuit Ampacity¹

49

49

47

24

24

Max. Overcurrent Protection (amps)²

60

60

60

30

30

Entrance Power Supply

Locating

Dimple

Locating

Dimple

Locating

Dimple

Locating

Dimple

Locating

Dimple

Entrance Control Voltage

Operating Weight (lbs)

1135

1050

1050

1135

1050

Ship Weight (lbs)

1175

1125

1125

1175

1125

¹ Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.

² May use fuses or HACR-type circuit breakers of the same size as noted.

Notes

• Always check the S&R plate for electrical data on the unit being installed.

• When a factory-installed powered convenience outlet is installed in the equipment, the unit MCA (Min. Circuit Ampacity) will increase by 7.5A for

208/230V units, increase by 3.75A for 460V units, and by 3A for 575V units. The MOP (Max. Overcurrent Protection) device must be sized accordingly.