beautypg.com

Product specs — 7½ tons, 7½ t, Roduct – Goodman Mfg CPC CONVERCIAL SS-CPC90-150 User Manual

Page 3: Pecifications

background image

2

www.goodmanmfg.com

SS-CPC90-150

SS-CPC90-150

www.goodmanmfg.com

3

P

roduct

S

PecificationS

P

roduct

S

PecificationS

P

roduct

S

PecificationS

— 7½ t

onS

CPC090

***3B***B*

CPC090

***3B***C*

CPC090

***4B***B*

CPC090

***4B***C*

CPC090

***7B***B*

CPC090

***7B***C*

Cooling Capacity
Total BTU/h

90,000

88,000

90,000

88,000

90,000

88,000

Sensible BTU/h

64,000

65,100

64,000

65,100

64,000

65,100

EER / IEER

11.5 / 11.5

11.3 / 11.5

11.5 / 11.5

11.3 / 11.5

11.5 / 11.5

11.3 / 11.5

Decibels

82

82

82

82

82

82

AHRI Reference #s

5104770

5589862

5104770

5589862

5104770

5589862

Evaporator Motor / Coil
Motor Type

Belt Drive

Belt Drive

Belt Drive

Belt Drive

Belt Drive

Belt Drive

Indoor Nominal CFM

3,000

3,000

3,000

3,000

3,000

3,000

Indoor Motor FLA (Cooling)

5.0

5.0

2.5

2.5

2.3

2.3

Horsepower / RPM

1.5 / 1745

1.5 / 1745

1.5 / 1745

1.5 / 1745

1.5 / 1725

1.5 / 1725

Piston Size (Cooling)

0.078

0.078

0.078

0.078

0.078

0.078

Filter Size (Qty)

16 x 20 x 2

16 x 20 x 2

16 x 20 x 2

16 x 20 x 2

16 x 20 x 2

16 x 20 x 2

Drain Size (NPT)

¾"

¾"

¾"

¾"

¾"

¾"

R-410A Refrigerant Charge Cir #1 & #2

175

100 oz.

175

100 oz.

175

100 oz.

Evaporator Coil Face Area (ft²)

8.9

8.9

8.9

8.9

8.9

8.9

Rows Deep / Fins per Inch

4 / 16

4 / 16

4 / 16

4 / 16

4 / 16

4 / 16

Belt Drive Evap Fan Data
# of Wheels (D x W)

1 (15" x 12")

1 (15" x 12")

1 (15" x 12")

1 (15" x 12")

1 (15" x 12")

1 (15" x 12")

Motor Sheave / Blower Sheave

VL40 / AK74

VL40 / AK74

VL40 / AK74

VL40 / AK74

VL40 / AK74

VL40 / AK74

Belt

AX51

AX51

AX51

AX51

AX51

AX51

Condenser Fan / Coil
Quantity of Condenser Fan Motors

2

2

2

2

2

2

Horsepower - RPM

¼ - 1075

¼ - 1075

¼ - 890

¼ - 890

¼ - 1,075

¼ - 1,075

Fan Diameter / # Fan Blades

22 / 4

22 / 4

22 / 4

22 / 4

22 / 4

22 / 4

Outdoor Nominal CFM

7,200

7,200

7,200

7,200

7,200

7,200

Face Area (ft²)

36

28.8

36

28.8

36

28.8

Rows Deep / Fins per Inch

2 / 22

2 X2 / 27±1

2 / 22

'2 X2 / 27±1

2 / 22

'2 X2 / 27±1

Compressor
Quantity / Type / Stage

2 / Scroll / 1

2 / Scroll / 1

2 / Scroll / 1

2 / Scroll / 1

2 / Scroll / 1

2 / Scroll / 1

Compressor RLA / LRA

13.1 / 83.1

13.1 / 83.1

6.1 / 41.0

6.1 / 41.0

4.4 / 33.0

4.4 / 33.0

Electrical Data
Voltage-Phase-Frequency

208/230-3-60

208/230-3-60

460-3-60

460-3-60

575-3-60

575-3-60

Max External Static

1.0"

1.0"

1.0"

1.0"

1.0"

1.0"

Outdoor Fan HP / RLA

(2) ¼ / 1.4

(2) ¼ / 1.4

(2) ¼ / 0.8

(2) ¼ / 0.8

(2) ¼ / 0.6

(2) ¼ / 0.6

Total Unit Amps

34.0

34.0

16.3

16.3

12.3

12.3

Min. Circuit Ampacity¹

37.3

37.3

17.8

17.8

13.4

13.4

Max. Overcurrent Protection (amps)²

50

50

20

20

15

15

Entrance Power Supply

Locating

Dimple

Locating

Dimple

Locating

Dimple

Locating

Dimple

Locating

Dimple

Locating

Dimple

Entrance Control Voltage

Operating Weight (lbs)

975

1010

975

1010

975

1010

Ship Weight (lbs)

1000

1085

1000

1085

1000

1085

¹ Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.

² May use fuses or HACR-type circuit breakers of the same size as noted.

Notes

• Always check the S&R plate for electrical data on the unit being installed.

• When a factory-installed powered convenience outlet is installed in the equipment, the unit MCA (Min. Circuit Ampacity) will increase by 7.5A for

208/230V units, increase by 3.75A for 460V units, and by 3A for 575V units. The MOP (Max. Overcurrent Protection) device must be sized accordingly.