Power cord – Grizzly G0444 User Manual
Page 30

-28-
G0444/G0444Z 10" Table Saw
Figure 37.
G0444 Wiring.
G0444
Motor
Wired For 110V
Green Ground
1
2
3
4
Black/White
Intrchangeable
Power Cord
- 110V Power Source
Figure 38.
G0444Z Wiring.
G0444Z
Motor
Wired For 220V
Power Cord
- 220V Power Source
Green Ground
3
4
1
2
Black/White
Intrchangeable
Power Cord
G0444
The Model G0444 ia prewired to operate on a
110V power source. Connect the power cord to
the motor according to
Figure 37
.
G0444Z
The Model G0444Z ia prewired to operate on a
220V power source. Connect the power cord to
the motor according to
Figure 38
.
!
Disconnect power to
the machine during the
entire assembly
process. Failure to do
this may result in seri-
ous personal injury.
Note—
Refer to Section 3: Circuit Requirements
and the wiring diagram at the back of this manu-
al for information on rewiring the G0444 for 220V
and the G0444Z for 110V.
- G0506 (56 pages)
- 12" Cold Cut Saw G0682 (52 pages)
- G1127 (3 pages)
- 24" & 27" Resaw Bandsaws G3619 (56 pages)
- H7197 (1 page)
- INDUSTRIAL BANDSAW W/FOOT BRAKE G0513X2F (108 pages)
- Heavy-Duty Table G1023Z (63 pages)
- G0641 (56 pages)
- Air Cut-Off G8122 (2 pages)
- Ultimate 14" Bandsaw G0555 (68 pages)
- G4186Z (48 pages)
- H8145 (36 pages)
- G0691 (11 pages)
- G0691 (92 pages)
- G0592 (60 pages)
- Model G1022proz (84 pages)
- G0605X1-6X1 (12 pages)
- Model G1023zx3 (63 pages)
- G1016 (30 pages)
- H0604 (10 pages)
- ZX (63 pages)
- g0531b (8 pages)
- G3620 (56 pages)
- G1023SL (50 pages)
- G1023SLWX (3 pages)
- 50/65 Ton Ironworker G0647 (76 pages)
- Zero Clearance Table Insert H7396 (1 page)
- H7583 (28 pages)
- G0621 (60 pages)
- G0457 (64 pages)
- G0605X1 (101 pages)
- H0629 (3 pages)
- Slow Speed Cold Cut G0665 (40 pages)
- G0717 (60 pages)
- G0659 (60 pages)
- G0606X1 (12 pages)
- G0605X/G0606X (76 pages)
- G5787 (37 pages)
- G8599 (13 pages)
- T10131 (4 pages)
- G0513P (108 pages)
- G9906 (14 pages)
- G0513X2 (108 pages)
- G7211 (34 pages)
- G1052 (34 pages)