Frymaster H17 User Manual
Page 3

WARNING
Do not use water jets to clean this equipment.
DANGER
All wiring connections for this appliance
MUST be made in accordance
with the wiring diagrams furnished with the equipment. Wiring diagrams
are located on the inside of the fryer door.
WARNING
This equipment is intended for indoor use only. Do not install or operate
this equipment in outdoor areas.
Electrical Requirements
MODEL VOLTAGE
PHASE
WIRE
SERVICE
MIN.
SIZE
AWG
(mm2)
AMPS PER LEG
L1 L2 L3
H14 208
3
3
6
(16)
39
39
39
H14 240
3
3
6
(16)
34
34
34
H14 480
3
3
8
(10)
17
17
17
H14 220/380
3 4 6
(16)
21
21
21
H14 240/415
3 4 6
(16)
20
20
21
H14 230/400
3 4 6
(16)
21
21
21
208 3 3 6
(16)
39
39 39
240 3 3 6
(16)
34
34 34
220/380 3
4
6 (16) 21 21 21
ALL
EPH14
SERIES
(SOLID STATE)
240/415 3
4
6 (16) 20 20 20
H17 208
3
3
6
(16)
48
48
48
H17 240
3
3
6
(16)
41
41
41
H17 480
3
3
6
(16)
21
21
21
H17 220/380
3 4 6
(16)
26
26
26
H17 240/415
3 4 6
(16)
24
24
24
` 230/400
3
4 6
(16)
25
25
25
ALL 208
3
3
6
(16)
48
48
48
240 3 3 6
(16)
41
41 41
220/380 3
4
6 (16) 26 26 26
EPH17
SERIES
(SOLID STATE)
240/415 3
4
6 (16) 24 24 24
H22 208
3
3
4
(25)
61
61
61
H22 240
3
3
4
(25)
53
53
53
H22 480
3
3
6
(16)
27
27
27
H22 220/380
3 4 6
(16)
34
34
34
H22 240/415
3 4 6
(16)
31
31
31
H22 230/400
3 4 6
(16)
32
32
32