10. INSTALLATION


10-2

10.2 Display

Unit

The display unit can be installed using either of four methods as shown below.
Refer to the outline drawing page D-1, D-2, and D-3.

• Locate the unit away from exhaust pipes and vents.
• The mounting location should be well ventilated.
• Mount the unit where shock and vibration are minimal.

• Keep the display unit away from electromagnetic field generating equipment

such as motor, generator.

• Allow sufficient maintenance space and a sufficient slack in cables for

maintenance and repair.

Table Top and Overhead Mounting

TABLE TOP

OVERHEAD

Figure 10-2 Display unit mounting methods


Flush mounting type F

An optional flush mount kit type F is required. For details, see outline drawing
page D-3. (Name: Flush Mount Kit F, Type:

OP20-25, Code No.: 004-393-280)

Name Type

Code

No.

Qty

Self-tapping screw

5X20

000-162-609-10

4

Hex. bolt

M6X12 SUS304

000-162-897-10

2

Spring washer

M6 SUS304

000-158-855-10

2

Cosmetic

panel 20-013-1121 100-234-240