51
Decimal
25
[Description]
When the printer controller receives this byte the digital
value of the head voltage will be transmitted. This
command can be treated even if buffer is full
3.8.25 Request Temperature
[Name]
Request Temperature
[Format]
ASCII
SUB
Hex
1A
Decimal
26
[Description]
When the printer controller receives this byte the digital
value of the head temperature will be transmitted. This
command can be treated even if buffer is full
3.8.26 Sub command set
[Name]
Sub command set
[Format]
ASCII
ESC n
Hex
1B n
Decimal
27
n
[Range]
n: [-128;127]
[Description]
The n is the commands in the sub-set.
3.8.27 Upgrade command
[Name]
Upgrade command
[Format]
ASCII
ESC Z
Hex
1B 5A
Decimal 27
90
[Description]
Only used by the I/F-COM A/S upgrade programs.
3.8.28 Set auxiliary output
[Name]
Set auxiliary output
[Format]
ASCII
ESC p
n
Hex
1B 70
n
Decimal 27
112 n
[Description]
When this command is received then
the auxiliary output can be set.
If n = 0, then the output will be set to off