FUJITSU FTP604 User Manual
Page 25
12-02-2003
Page 3-25 of
- 3-25 -
51
3.8.21
Initialise Printer
[Name]
Initialise
[Format]
ASCII
SYN
Hex
16
Decimal
22
[Description]
When the printer controller receives this byte a reset of
the printer will be initialised. This command can be
treated even if buffer is full.
3.8.22 Request Software version
[Name]
Request software version
[Format]
ASCII
ETB
Hex
17
Decimal
23
[Description]
When the printer controller receives this byte the
software version will be transmitted. This command can
be treated even if buffer is full.
3.8.23 Request Status
[Name]
Request status
[Format]
ASCII
CAN
Hex
18
Decimal
24
[Description]
When the printer controller receives this byte a status
byte will be transmitted. This command can be treated
even if buffer is full.
The bit definitions is as follows
Bit Status
0
1
0
Near end
Logic level is low
Logic level is high
1
Paper
Present
Absent
2
Temperature
Not too hot
Head too hot to print
3
Head
Closed
Open
4
Paper Jam
No error
Error
5
Rxerror
No error
Rx error
6
Buffer
Not full.
Full (less than 16 bytes left)
7
Always 1.
3.8.24 Request Analog voltage.
[Name]
Analog voltage
[Format]
ASCII
EM
Hex
19