5-4
5. Press the [ENTER/SELECT] key to automatically adjust the video level. When
the adjustment has been completed a beep sounds (R-type only).
6. Connect an oscilloscope to TP6 on the pcb 03P9230 display unit) and mea-
sure main bang signal level. It should be 4.0 Vpp
±
0.2 V. If it is not, within that
range redo steps 4 and 5 above.
Manual adjustment
If the video signal level could not be adjusted automatically, adjust it manually as
follows.
1. Do steps 1-3 in automatic tuning.
2. Press the [4] key to select MAN from the VIDEO LVL field.
3. Press the [ENTER/SELECT] key.
4. Connect the oscilloscope to TP6 on the pcb 03P9230. Operate the EBL rotary
control while pressing and holding down the HL OFF control so the main bang
level is 4.0 Vpp
±
0.2 V.
TP19 (TRIG)
U92 (EEPOT)
TP6
(Video Signal)
Figure 5-6 pcb 03P9230
- FAR-2805 Series (169 pages)
- FR-8062 (2 pages)
- FR-8122 (56 pages)
- CH-37 (71 pages)
- CH-37 (90 pages)
- FAR-2XX7 (4 pages)
- FAR-2XX7 (2 pages)
- FELCOM16 (4 pages)
- FRS-1000B (8 pages)
- FRS1000 (8 pages)
- Ls4100 (48 pages)
- 520 (73 pages)
- Marine Radar (24 pages)
- 1944C-BB (233 pages)
- 1733C (260 pages)
- FR-2105 (197 pages)
- FMD-8010 (50 pages)
- GD-1900C (260 pages)
- Black Box Video Sounder FCV-1200BB (2 pages)
- FR-1505 MARK-3 (4 pages)
- 1762 (252 pages)
- NAVnet DRS12A (44 pages)
- FAR-2137S (8 pages)
- FAR-2127 (136 pages)
- FA30 (6 pages)
- Satellite Compass SC-50/110 (30 pages)
- 1715 (2 pages)
- 1715 (48 pages)
- 1734C (55 pages)
- GD-1720C (53 pages)
- Mu 120c (2 pages)
- NAVNET GD-1920C (239 pages)
- CI-80 (41 pages)
- FAR-28x7 Series (299 pages)
- FAR-2837S (8 pages)
- BBWX1 (2 pages)
- 851 MARK-2 (37 pages)
- 851 MARK-2 (47 pages)
- BBFF3 (1 page)
- CSH-53 (106 pages)
- CSH-53 (108 pages)
- FCV295 (53 pages)
- FI-50 Series (2 pages)
- FCV-1150 (32 pages)