INSTALLATION AND CLEARANCES
(Vent-Free Operation Only)

WARNING: Maintain the

minimum clearances. If you can,

provide greater clearances from

floor, ceiling and adjoining wall.

MINIMUM FIREPLACE CLEARANCE

TO COMBUSTIBLE MATERIALS

Side Wall 16", Ceiling 42"

LOG SIZING REQUIREMENTS

Minimum Firebox

Log

Size Height Depth

Front

Width

Rear

Width*

18"

17"

14"

24"

20"

24"

17"

14"

28"

21"

* Measured at 14" depth.

Carefully follow the instructions below. This

will ensure safe installation into a masonry,

UL127-listed manufactured fireplace or certi-

fied vent-free firebox.
Minimum Clearances For Side Combus-

tible Material, Side Wall and Ceiling

A. Clearances from side of fireplace cabinet

to any combustible material and wall

should follow diagram in Figure 4.

Example: The face of a mantel, bookshelf,

etc. is made of combustible material and

protrudes 3

1

/

2

" from the wall. This com-

bustible material must be 4" from side of

fireplace opening (see Figure 4).

Note: When installing your gas logs into

a manufactured firebox, follow firebox

manufacturer’s instructions for minimum

clearances to combustible materials.

B. Clearances from top of fireplace opening

to ceiling should not be less than 42".

INSTALLATION

Continued

Figure 4 - Minimum Clearance for

Combustible to Wall

*Minimum 16" from Side Wall

Example

*

WARNING: Never install the

heater

• in a bedroom or bathroom

• in a recreational vehicle

• where curtains, furniture,

clothing or other flammable

objects are less than 42" from

front, top or sides of heater

• in high traffic areas

• in windy or drafty areas

CAUTION: This heater cre-

ates warm air currents. These

currents move heat to wall sur-

faces next to heater. Installing

heater next to vinyl or cloth wall

coverings or operating heater

where impurities (such as, but

not limited to, tobacco smoke,

aromatic candles, cleaning flu-

ids, oil or kerosene lamps, etc.) in

the air exist, may discolor walls

or cause odors.

IMPORTANT: Vent-free heaters add moisture

to the air. Although this is beneficial, installing

heater in rooms without enough ventilation

air may cause mildew to form from too much

moisture. See Air for Combustion and Ventila-

tion, page 6.

CHECK GAS TYPE

Use the correct gas type (natural or propane/

LP) for your unit. If your gas supply is not cor-

rect, do not install heater. Call dealer where

you bought heater for proper type heater.

WARNING: This appliance is

equipped for either natural gas

or propane/LP gas but not both.

Gas type is indicated on the rat-

ing plate. Field conversion is not

permitted.