TROUBLESHOOTING

Continued

POSSIBLE CAUSE

1. Not enough combustion/

ventilation air

1. Turning control knob to HI

or position 5 when burner is

cold

2. Air in gas line

3. Air passageways on heater

blocked

4. Dirty or partially clogged

burner orifice

1. When heated, vapors from

furniture polish, wax, carpet

cleaners, etc. may turn into

white powder residue

1. Metal expanding while

heating or contracting while

cooling

REMEDY

1. Refer to Air for Combustion

and Ventilation require-

ments (page 6)

1. Turn control knob to LO or

position 1 and let warm up

for a minute

2. Operate burner until air is

removed from line. Have

gas line checked by local

propane/LP or natural gas

company

3. Observe minimum installation

clearances (see page 9)

4. Clean burner (see Cleaning

and Maintenance, page 03)

or replace burner orifice

1. Turn heater off when us-

ing furniture polish, wax,

carpet cleaners or similar

products

1. This is normal with most

heaters. If noise is exces-

sive, contact qualified ser-

vice person

OBSERVED PROBLEM

Moisture/condensation no-

ticed on windows

Heater produces a whistling

noise when burner is lit

White powder residue form-

ing within burner box or on

adjacent walls or furniture

Heater produces a clicking/

ticking noise just after burner

is lit or shut off