Cleaning and maintenance, Service hints, Technical service – FMI CCL3018PTA/NTA User Manual

Page 21

background image

www.fmiproducts.com

124971-01C

21

1. Shut off unit, including pilot. Allow unit to

cool for at least thirty minutes.

2. Inspect burner, pilot and primary air inlet

holes on injector holder for dust and dirt

(see Figure 28).

3. Blow air through the ports/slots and holes

in the burner.

4. Check the injector holder located at the

end of the burner tube again. Remove

any large particles of dust, dirt, lint or pet

hair with a soft cloth or vacuum cleaner

nozzle.

5. Blow air into the primary air holes on the

injector holder.

6. In case any large clumps of dust have now

been pushed into the burner repeat steps

3 and 4.

Clean pilot assembly also. A yellow tip on the

pilot flame indicates dust and dirt in the pilot

assembly. There is a small pilot air inlet hole

about 2" from where the pilot flame comes out

of the pilot assembly (see Figure 29). With the

unit off, lightly blow air through the air inlet

hole. You may blow through a drinking straw

if compressed air is not available.

CLEANING AND MAINTENANCE

Continued

Figure 28 - Injector Holder On Outlet

Burner Tube

Burner Tube

Primary Air

Inlet Holes

Injector Holder

Figure 29 - Pilot Inlet Air Hole

Burner Tube

Pilot Assembly

Pilot Air

Inlet Hole

Ports/Slots

LOGS

• If you remove logs for cleaning, refer to

Installing Logs, page 16, to properly replace

logs.

• Replace log(s) if broken or chipped (dime-

sized or larger).

MAIN BURNER

Periodically inspect all burner flame holes with

the heater running. All slotted burner flame

holes should be open with yellow flame pres-

ent. All round burner flame holes should be

open with a small blue flame present. Some

burner flame holes may become blocked by

debris or rust, with no flame present. If so,

turn off heater and let cool. Remove blockage.

Blocked burner flame holes will create soot.

SERVICE HINTS

When Gas Pressure Is Too Low

• pilot will not stay lit
• burners will have delayed ignition
• heater will not produce specified heat
• for propane/LP units, propane/LP gas sup-

ply may be low

You may feel your gas pressure is too low. If

so, contact your local propane/LP or natural

gas supplier.

TECHNICAL SERVICE

You may have further questions about

installation, operation, or troubleshooting.

If so, contact FMI PRODUCTS, LLC at

1-866-328-4537. When calling please have

your model and serial numbers of your

heater ready.
You can also visit FMI PRODUCTS, LLC’s

web site at

www.fmiproducts.com.