beautypg.com

Installation – FMI CCL3018PTA/NTA User Manual

Page 12

background image

www.fmiproducts.com

124971-01C

12

INSTALLATION

Continued

INSTALLING HEATER BASE

ASSEMBLY

CAUTION: Do not remove the

data plates attached to the heater

base assembly. The data plates

contain important warranty and

safety information.

WARNING: You must secure

this heater to fireplace floor. If

not, heater will move when you

adjust controls. Moving heater

may cause a gas leak.

WARNING: If installing in a

sunken fireplace, special care

is needed. You must raise the

fireplace floor to allow access

to heater control panel. This

will insure adequate air flow

and guard against sooting and

controls being damaged. Raise

fireplace floor with noncombus-

tible material. Make sure material

is secure.

CAUTION: Do not pick up

heater base assembly by the

burner. This could damage

heater. Only handle base as-

sembly by grates.

IMPORTANT: Make sure the heater burners

are level. If heater is not level, heater will not

work properly. For thermostat models, avoid

damage to thermostat bulb. Avoid nicks or

sharp bends in thermostat bulb wire. Keep

thermostat bulb in mounting bracket until

ready to mount base to floor. See Optional

Positioning Of Thermostat Sensing Bulb,

page 22.

Figure 10 - Attaching Flexible Gas Hose

to Heater Gas Regulator

Heater Gas

Regulator

Flexible Gas Hose

(if allowed by local codes)

Fitting

Installation Items Needed

• hardware package (provided with heater)

• approved flexible gas hose (not provided)

(if allowed by local codes)

• sealant resistant to propane (propane/LP)

gas, not provided

• electric drill with 3/16" drill bit

• flathead screwdriver
1. Apply pipe joint sealant lightly to male

threads of the fitting to be threaded into

gas regulator. Connect approved flexible

gas hose to gas regulator of heater (see

Figure 10).

IMPORTANT: Hold gas regulator with

wrench when connecting flexible gas hose.

2. Locate masonry screws in hardware

package.

3. Position heater base assembly in fireplace.
4. Place logs in their proper position on heater

base, see Installing Logs on page 16.

5. Center heater base and logs front-to-back

and side-to-side in fireplace.

6. Carefully remove logs without moving

heater base.

7. Mark screw locations through holes in

mounting brackets (see Figure 11 on

page 13). If installing in a brick-bottom

fireplace, mark screw locations in mortar

joint of bricks.

8. Remove heater base from fireplace.
9. Drill holes at marked locations using 3/16"

drill bit.

10. Attach base assembly to fireplace floor

using two masonry screws (in hardware

package) (see Figure 11 on page 13).