Figure 1 - Vent-Free Gas Log Heater

Base Grate

Log Set

Control Knob

Burner

Piezo

Ignitor

PRODUCT IDENTIFICATION

State of Massachusetts: The installa-

tion must be made by a licensed plumber

or gas fitter in the Commonwealth of

Massachusetts.
Sellers of unvented propane or natural

gas-fired supplemental room heaters shall

provide to each purchaser a copy of 527

CMR 30 upon sale of the unit.
Vent-free gas products are prohibited for

bedroom and bathroom installation in the

Commonwealth of Massachusetts.

LOCAL CODES

Install and use heater with care. Follow all

local codes. In the absence of local codes,

use the latest edition of The National Fuel

Gas Code, ANSI Z223.1/NFPA 54*.
*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

Note: Where listed vented decorative logs are re-

quired, thermostat operation is not permitted.

UNPACKING

CAUTION: Do not remove the

data plates from the grate as-

sembly. The data plates contain

important product information.

1. Remove logs and heater base assembly

from carton. Note: Do not pick up heater

base assembly by burners. This could

damage heater. Always handle base as-

sembly by grate.

2. Remove all protective packaging applied

to logs and heater for shipment.

3. Check heater for any shipping damage. If

heater is damaged call FMI PRODUCTS,

LLC at 1-866-328-4537 for replacement

parts. Please do not return to the store.

PRODUCT FEATURES

OPERATION

This heater is clean burning. It requires no outside

venting. There is no heat loss out a vent or up

a chimney. Heat is generated by realistic danc-

ing, yellow flames. This heater is designed for

vent-free operation with flue damper closed. It

has been tested and approved to ANSI Z21.11.2

standard for unvented heaters. State and local

codes in some areas prohibit the use of vent-

free heaters.

SAFETY PILOT

This heater has a pilot with an Oxygen Deple-

tion Sensing (ODS) safety shutoff system. The

ODS/pilot is a required feature for vent-free

room heaters. The ODS/pilot shuts off the

heater if there is not enough fresh air.

PIEZO IGNITION SYSTEM

This heater has a piezo ignitor. This system re-

quires no matches, batteries or other sources

to light heater.