INSTALLATION

Continued

Figure 11 - Attaching Base Assembly to

Fireplace Floor - Dual Burner Model

Masonry

Screw

Mounting

Bracket

CONNECTING TO GAS SUPPLY

WARNING: This appliance

requires a 1/2" NPT (National

Pipe Thread) inlet connection to

the pressure regulator.

WARNING: A qualified ser-

vice person must connect heater

to gas supply. Follow all local

codes.

CAUTION: Never connect

heater directly to the propane/LP

supply. This heater requires an

external regulator (not supplied).

Install the external regulator be-

tween the heater and propane/

LP supply.

WARNING: Never connect

natural gas fireplace to private

(non-utility) gas wells. This

gas is commonly known as

wellhead gas.

Installation Items Needed

Before installing heater, make sure you have

the items listed below.
• external regulator (supplied by installer)
• piping (check local codes)
• sealant (resistant to propane/LP gas)
• equipment shutoff valve *
• test gauge connection *
• sediment trap
• tee joint
• pipe wrench
* An equipment shutoff valve with 1/8" NPT

tap is an acceptable alternative to test gauge

connection. Purchase the optional equipment

shutoff valve from your dealer. See Acces-

sories, page 30.
For propane/LP units, the installer must

supply an external regulator. The external

regulator will reduce incoming gas pressure.

You must reduce incoming gas pressure to

between 11" and 14" of water. If you do not re-

duce incoming gas pressure, heater regulator

damage could occur. Install external regulator

with the vent pointing down as shown in Figure

12. Pointing the vent down protects it from

freezing rain or sleet.

Figure 12 - External Regulator With Vent

Pointing Down

Propane/LP

Supply Tank

External

Regulator

with Vent

Pointing

Down