OPTIONAL POSITIONING OF THERMOSTAT SENSING BULB

Thermostat

Sensing

Bulb

Gas Valve

Assembly

Mounting

Bracket

Figure 30 - Location of Gas Valve

Assembly and Thermostat Sensing Bulb

Figure 31 - Removing Thermostat

Sensing Bulb

Thermostat Screw

Retaining

Clamp

Thermostat

Sensing

Bulb

Capillary

FOR MASONRY AND FACTORY-

BUILT METAL FIREPLACE

If your log set cycles to pilot, but the room

temperature drops to a lower than ideal

comfort level before the log set comes back

on, you may want to reposition the thermostat

sensing bulb.
The thermostat sensing bulb is located on the

gas valve assembly. This location allows the

thermostat to keep the room temperature at

an ideal comfort level for most fireplace appli-

cations. If positioning the thermostat sensing

bulb elsewhere, follow these directions.
Tools needed: 5/16" hex driver or socket
1. Locate the gas valve assembly and ther-

mostat sensing bulb (see Figure 30).

2. With 5/16” hex driver or socket, loosen

the thermostat screw. Carefully slide the

thermostat sensing bulb out of the retain-

ing clamp (see Figure 31).

Note: Do not remove screw. Make sure

you tighten screw after removing thermo-

stat sensing bulb.

IMPORTANT: Do not force or bend ther-

mostat sensing bulb or capillary.

3. The thermostat sensing bulb may be

located to the lower right front side of

fireplace. Place bulb in an area that will

be close to room temperature when log

set is operating