b. Move head to reference cylinder

Drives the VCM to position the head at the any cylinder in the data area. The logical initial
cylinder is at the outermost circumference (cylinder 0).

c.

Seek to specified cylinder

Drives the VCM to position the head to the specified cylinder.

d. Calibration

Senses and stores the thermal offset between heads and the mechanical forces on the actuator,
and stores the calibration value.