FUJITSU MPG3XXXAH-E User Manual
Page 125
5 - 58
C141-E116-01EN
*9 Off-line data collection capability [16Fh]
Bit
Description
0
If this bit is set to 1, it indicates SMART EXECUTE OFF-LINE
IMMEDIATE subcommand is supported. (FR register = D4)
1
Vendor unique
2
If this bit is set to 1, it indicates off-line data collection being
aborted when a new command is received.
3
If this bit is set to 1, it indicates SMART off-line read scanning is
supported.
4
If this bit is set to 1, it indicates SMART Self Test is supported.
5 to 7
Reserved bits
*10
SMART capability flag [170-171h]
Bit
Description
0
If this bit is set to 1, it indicates the attribute data is saved to the
media before the drive enters power save mode.
1
If this bit is set to 1, it indicates the device saves the attribute
automatically according to fixed operation.
2-15
Reserved bits
*11
Drive error logging capability [172h]
Bit
Description
0
If this bit is set to 1, it indicates the drive error logging is
supported.
1 to 15
Reserved bits
*12
Quick Test completion time [minutes]
This value indicates the processing time of the Quick Test (off-line mode).
*13
Comprehensive Test completion time [minutes]
This value indicates the processing time of the Comprehensive Test (off-line mode).
*14
Check sum
Twos complement of the lower byte, obtained by adding 511-byte data one by at a time from
the beginning.