beautypg.com

FUJITSU MPG3XXXAH-E User Manual

Page 134

background image

C141-E116-01EN

5 - 67

READ DMA

WRITE LONG

SECURITY DISABLE PASSWORD

READ LONG

WRITE MULTIPLE

SECURITY FREEZE LOCK

READ MULTIPLE

WRITE SECTORS

SECURITY SET PASSWORD

READ SECTORS

WRITE VERIFY

FORMAT TRACK

READ VERIFY

SET MAX ADDRESS

FLASH CACHE

WRITE DMA

At command issuance (I-O registers setting contents)

1F7

H

(CM)

1

1

1

1

0

1

0

1

1F6

H

(DH)

Ч

Ч

Ч

DV

xx

1F5

H

(CH)

1F4

H

(CL)

1F3

H

(SN)

1F2

H

(SC)

1F1

H

(FR)

xx
xx
xx
xx
xx

At command completion (I-O registers contents to be read)

1F7

H

(ST)

Status information

1F6

H

(DH)

Ч

Ч

Ч

DV

xx

1F5

H

(CH)

1F4

H

(CL)

1F3

H

(SN)

1F2

H

(SC)

1F1

H

(ER)

xx
xx
xx
xx

Error information

(34)

SECURITY SET PASSWORD (F1h)

This command enables a user password or master password to be set.

The host transfers the 512-byte data shown in Table 5.15 to the device. The device determines the
operation of the lock function according to the specifications of the Identifier bit and Security level
bit in the transferred data. (Table 5.16)

Issuing this command in LOCKED MODE or FROZEN MODE returns the Aborted Command
error.