Information to be read by IDENTIFY DEVICE command (6 of 6)
*20 Word 89: Time required for SECURITY ERASE UNIT command to complete.
MPG3204AH-E = 0004H: 8 minutes
MPG3307AH-E = 0006H: 12minutes
MPG3409AH-E = 0008H: 16 minutes
*21 Word 93: Hardware reset result. The contents of bits 12-0 of this word shall change only during the
execution of a hardware reset.
Bit 15:
0
Bit 14:
1
Bit 13:
1 = device detected CBLID- above V
IH
(80-conductor cable)
0 = device detected CBLID- below V
IL
(40-conductor cable)
Bit 12-8:
Device 1 hardware reset result. Device 0 shall clear these bits to zero.
Device 1 shall set these bits as follows:
Bit 12:
0 = Reserved
Bit 11:
0 = Device 1 did not assert PDIAG-
1 = Device 1 asserted PDIAG-
Bit 10-9: These bits indicate how Device 1 determined the device number.
00 = Reserved
01 = a jumper was used
10 = the CSEL signal was used
11 = some other method was used or the method is unknown
Bit 8:
1
Bit 7-0:
Device 0 hardware reset result. Device 1 shall clear these bits to zero.
Device 0 shall set these bits as follows:
Bit 7:
0
Bit 6:
0 = Device 0 does not respond when Device 1 is selected
1 = Device 0 responds when Device 1 is selected
Bit 5:
0 = Device 0 did not detect the assertion of DASP-
1 = Device 0 detected the assertion of DASP-
Bit 4:
0 = Device 0 did not detect the assertion of PDIAG-
1 = Device 0 detected the assertion of PDIAG-
Bit 3:
0 = Device 0 failed diagnostics
1 = Device 0 passed diagnostics
Bit 2-1:
These bits indicate how Device 0 determined the device number.
00 = Reserved
01 = a jumper was used
10 = the CSEL signal was used
11 = some other method was used or the method is unknown
Bit 0:
1
*22 Word 94: Automatic Acoustic Management
Bit 15-8:
0
Bit 7-0:
Current automatic acoustic management value