1 - 6

(3)

Current Requirements and Power Dissipation

Table 1.3 lists the current and power dissipation.

Table 1.3

Current and power dissipation

Typical RMS current (*1) [mA]

Mode of Operation

+12 V

+5 V

Typical Power (*2) [watts]

Model

MPG

3204AH-E

MPG

3307AH-E

MPG

3409AH-E

All

Models

MPG

3204AH-E

MPG

3307AH-E

MPG

3409AH-E

Spin up

1950 peak

1950 peak

1950 peak

800 peak

27.4

27.4

27.4

Idle (Ready) (*3)

350

400

400

490

6.7

7.3

7.3

R/W (On Track) (*4)

370

450

450

600

7.4

8.4

8.4

Seek (Random) (*5)

480

540

540

570

8.6

9.3

9.3

Standby

18

18

18

120

0.8

0.8

0.8

Sleep

18

18

18

120

0.8

0.8

0.8

Energy efficiency (rank) (*6) [watt / GB]

0.327 (A)

0.237 (B)

0.178 (B)

*1

Current is typical rms except for spin up.

*2

Power requirements reflect nominal values for +12V and +5V power.

*3

Idle mode is in effect when the drive is not reading, writing, seeking, or executing any commands. A portion of the R/W circuitry is powered down,
the spindle motor is up to speed and the Drive ready condition exists.

*4

R/W mode is defined as 50% read operations and 50% write operations on a single physical track.

*5

Seek/W/R mode is defined as 33% seek operations, 33% write operations, and 33% read operations.

*6

Energy efficiency based on the Law concerning the Rational Use of Energy indicates the value obtained by dividing power consumption by the storage
capacity. (Japan only)