beautypg.com

FUJITSU MPG3XXXAH-E User Manual

Page 138

background image

C141-E116-01EN

5 - 71

At command issuance (I/O registers setting contents)

1F7

H

(CM)

1

1

1

1

1

0

0

1

1F6

H

(DH)

×

L

×

DV

Max head/LBA [MSB]

1F5

H

(CH)

1F4

H

(CL)

1F3

H

(SN)

Max. cylinder [MSB]/Max. LBA
Max. cylinder [LSB]/Max. LBA
Max. sector/Max. LBA [LSB]

1F2

H

(SC)

xx

VV

1F1

H

(FR)

xx

At command completion (I/O registers contents to be read)

1F7

H

(ST)

Status information

1F6

H

(DH)

Ч

Ч

Ч

DV

Max head/LBA [MSB]

1F5

H

(CH)

1F4

H

(CL)

1F3

H

(SN)

1F2

H

(SC)

1F1

H

(ER)

Max. cylinder [MSB]/Max. LBA
Max. cylinder [LSB]/Max. LBA
Max. sector/Max. LBA [LSB]
xx
Error information

(36-2)

SET MAX SET PASSWORD (F9)

This command requests a transfer of single sector of data from the host, and defines the content of
this sector of information. The password is retained by the device until the next power cycle.

At command issuance (I/O registers setting contents)

1F7

H

(CM)

1

1

1

1

1

0

0

1

1F6

H

(DH)

1

L

1

DV

xx

1F5

H

(CH)

1F4

H

(CL)

1F3

H

(SN)

1F2

H

(SC)

xx
xx
xx
xx

1F1

H

(FR)

0

0

0

0

0

0

0

1