beautypg.com

FUJITSU MPG3XXXAH-E User Manual

Page 124

background image

C141-E116-01EN

5 - 57

*7 Off-line data collection status

Values

Description

00h or 80h

Off-line data collection is not started.

01h or 81h

Reserved

02h or 82h

Off-line data collection has been completed without error.

03h or 83h

Reserved

04h or 84h

Off-line data collection has been suspended by an interrupt
command from the host.

05h or 85h

Off-line data collection has been aborted by an interrupt command
from the host.

06h or 86h

Off-line data collection has been aborted with a fatal error. (Not
used)

40h to 7Fh

C0h to FFh

Vendor unique (Not used)

07h to 3Fh

87h to BFh

Reserved

If bit [7] is 1, it indicates that automatic off-line data collection function is enabled.

*8 Self Test execution status byte [16Bh]

Bit 0-3: Self Test remain time.

The values in these bits indicate the remaining percentage (0% - 90%) of Self Test until
completion by 0h-9h.

Bit 4-7: Self Test execution status

00h:

Self Test has been completed normally. Otherwise Self Test has not

performed.
01h:

Self Test has been interrupted by host.

02h:

Self Test has been interrupted by the soft/hard reset from the host.

03h:

Self Test has been aborted for a final error.

04h:

Self Test has been completed abnormally for an unknown meaning.

05h:

Self Test has been completed abnormally by Write/Read Test.

06h:

Self Test has been completed abnormally by servo analysis.

07h:

Self Test has been completed abnormally by Read Scan Test

08h-0Eh:

Reserved

0Fh:

Self Test is being performed.