5.2 Remedying Common Troubles

fi-4530C Image Scanner Operator’s Guide

89

TROUBLESHO

OTING

5

*) For details on how to clean dirty locations, refer to "3 DAILY CARE" on page 51.

Clean dirty locations.(*)

YES

Do not press down the ADF
or place heavy objects on the
ADF during scanning.

NO

YES

Is the ADF cover pressed down
or heavy object placed on the ADF
during scanning?

YES

Do not allow anything to
cause the scanner to
vibrate while scanning.

Is something causing the scanner
to vibrate during scanning?

NO

NO

Symptom6

Images are distorted or blurred.

Is the glass clean?

YES

Contact the manufacturer’s
authorized service center.

Is the scanner not installed on a
flat, level surface or is a scanner’s
rubber foot missing?

Install the scanner on a flat,
level surface or attach rubber
the foot.

NO