beautypg.com

15 troubleshooting the autofill system – Frymaster 17EC User Manual

Page 47

background image

6-15

TROUBLESHOOTING THE AUTOFILL SYSTEM

Verify that unit is connected to the
water supply and that water supply

is turned on.

Drain the water in the cookpot to a

level below the upper water-level

sensor.

Place the master ON/OFF switch

in the ON position.

Press the computer ON/OFF

switch.

Did unit

begin to fill?

Remove the water-

level sensor guard

and thoroughly clean

the sensors.

Did unit

begin to fill?

Did water

shut off when water

reached the upper water-level

sensor?

Yes

No

Is voltage across

Pins 2 and 6 of computer

15-pin connector zero?

No

Check sensor and wiring.

If they are NOT grounded,

the computer has failed.

Replace.

If they ARE grounded, repair

or replace as required.

No

If 24VAC is NOT present

across Pins 2 and 3 of the

contactor box 15-pin connector,

check connections and wiring to

solenoid valve. If wiring and

connections are intact, the valve

has failed. Replace.

Yes

Is 24VAC

present across Pins

2 and 6 of the computer

15-pin connector?

No

Yes

Autofill system is OK.

Yes

Check resistance

through Pins 2 and 9 of

the computer 15-pin

connector. If it is less than 1

ohm, the computer has failed.

Replace.

If it is 1 ohm or greater, repair

wiring between sensor and

computer or replace

sensor as required.

No

This manual is related to the following products: