When the water is at or above the minimum temperature for boiling (transition temperature), the
controller pulses power to the elements at a programmable rate. The range can be set between 0 and
9. The default setting is 5. When the water temperature is below boiling point, the power
application is 100 percent.
To set the Transition Temperature/Boil Intensity:
1. Verify that the controller is OFF (the display is blank).
2. Press the Simmer (right thermometer icon) switch to enter the programming mode; CODE appears
in the display.
3. Enter code 1111 (press the 1 button four times). Transition Temperature appears in the display.
(NOTE: If transition temperature does not appear, your controller is not configured with this
feature. Press the Simmer switch to exit the programming mode. The display will go blank.)
4. Enter the minimum temperature for boiling with the keypad. This temperature will vary with
your altitude. As a guide, the table below provides boiling points for altitudes from sea level to
6000 feet (1830 meters).
Altitude
Boiling Point
Feet
Meters
°F
°C
0
0
212
100
1000
305
210
99
2000
610
208
98
3000
915
207
97
4000
1220
205
96
5000
1525
203
95
6000
1830
201
94
5. Press the simmer switch; 5BI (the default setting for boil intensity) appears.
6. Use the keypad to enter one of the settings from the table below.
Setting
Power ON
Power OFF
0
100%
0%
9
90%
10%
8
80%
20%
7
70%
30%
6
60%
40%
5
50%
50%
4
40%
60%
3
30%
70%
2
20%
80%
1
10%
90%
7. Press the simmer switch to lock in the new settings and exit the programming mode. The display