3. If replacing the regulator, adjust the replacement regulator output pressure to not more than 40

PSI (28.15 kg/cm

2

) before installation in the cooker.

4. Recover the fittings from the failed component (regulator or solenoid valve) and install them on

the replacement, using thread sealer on all connections.

5. Reverse Steps 1 and 2 to complete the procedure, being sure to apply thread sealer to all

connections. NOTE: The regulator must be rotated approximately 45 degrees to clear the drain
plumbing (see illustration at Step 2).

6.3.8

Replacing the Water Faucet

1. Drain the cookpot and disconnect the cooker from the electrical power supply.

2. Turn off the water supply to the cooker and disconnect the incoming water lines where they

attach to the stubs at the rear of the cooker.

3. Remove the two screws securing the access panel in place and remove the panel.

4. Disconnect the water supply line at the compression fitting where it attaches to the water inlet

manifold. Remove the screws from the faucet mounting plate and lift the faucet assembly from
the unit.

Disconnect this

compression fitting.

Remove screws to remove the

faucet mounting plate.

Loosen this nut to separate

the faucet from the water

inlet manifold.

Remove this nut to separate the

faucet from the mounting plate.

5. Separate the faucet from the water inlet manifold and mounting plate as shown in the illustration

at Step 4.

6. Reverse Steps 1-5 to complete the procedure.

6.3.9

Replacing a Basket Lift Motor or Microswitch

1. Disconnect the cooker from the electrical power supply.